Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

    ATV212HD22N4S Product picture Schneider Electric

    Range: Altivar 212

    HVAC solutions

    ATV212HD22N4S

    ATV212HD22N4S Product picture Schneider Electric
    Range: Altivar 212

    HVAC solutions

    ATV212HD22N4S

    variable speed drive ATV212 - 22kW - 30hp - 480V - 3ph - EMC - IP21

    Show more characteristics >
    Add to My Favourites Remove from My Favourites

    • Main
      range of product
      Altivar 212
      product or component type
      Variable speed drive
      device short name
      ATV212
      product destination
      Asynchronous motors
      product specific application
      Pumps and fans in HVAC
      assembly style
      With heat sink
      network number of phases
      3 phases
      motor power kW
      22 kW
      motor power hp
      30 hp
      [Us] rated supply voltage
      380...480 V - 15...10 %
      supply voltage limits
      323...528 V
      supply frequency
      50...60 Hz - 5...5 %
      network frequency
      47.5...63 Hz
      EMC filter
      Class C2 EMC filter integrated
      line current
      41.1 A 380 V
      32.6 A 480 V
      Complementary
      apparent power
      27.3 kVA 380 V
      prospective line Isc
      22 kA
      continuous output current
      43.5 A 380 V
      43.5 A 460 V
      maximum transient current
      47.9 A 60 s
      speed drive output frequency
      0.5...200 Hz
      nominal switching frequency
      8 kHz
      switching frequency
      6...16 kHz adjustable
      8...16 kHz with derating factor
      speed range
      1...10
      speed accuracy
      +/- 10 % of nominal slip 0.2 Tn to Tn
      torque accuracy
      +/- 15 %
      transient overtorque
      120 % of nominal motor torque +/- 10 % 60 s
      asynchronous motor control profile
      Flux vector control without sensor, standard
      Voltage/frequency ratio, 2 points
      Voltage/frequency ratio - Energy Saving, quadratic U/f
      Voltage/frequency ratio, 5 points
      Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
      regulation loop
      Adjustable PI regulator
      motor slip compensation
      Automatic whatever the load
      Adjustable
      Not available in voltage/frequency ratio motor control
      local signalling
      1 LED red DC bus energized
      output voltage
      <= power supply voltage
      isolation
      Electrical between power and control
      type of cable
      IEC cable without mounting kit 1 45 °C copper 90 °C XLPE/EPR
      IEC cable without mounting kit 1 45 °C copper 70 °C PVC
      UL 508 cable with UL Type 1 kit 3 40 °C copper 75 °C PVC
      electrical connection
      Terminal 2.5 mm² AWG 14 VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES
      Terminal 25 mm² AWG 3 L1/R, L2/S, L3/T
      tightening torque
      4.5 N.m 40 lb.in L1/R, L2/S, L3/T
      0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES
      supply
      Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 % <= 10 A overload and short-circuit protection
      Internal supply 24 V DC 21...27 V <= 200 A overload and short-circuit protection
      analogue input number
      2
      analogue input type
      Switch-configurable voltage VIA 0...10 V DC 24 V max 30000 Ohm 10 bits
      Configurable voltage VIB 0...10 V DC 24 V max 30000 Ohm 10 bits
      Configurable PTC probe VIB 0...6 probes 1500 Ohm
      Switch-configurable current VIA 0...20 mA 250 Ohm 10 bits
      sampling duration
      2 ms +/- 0.5 ms F discrete
      2 ms +/- 0.5 ms R discrete
      2 ms +/- 0.5 ms RES discrete
      3.5 ms +/- 0.5 ms VIA analog
      22 ms +/- 0.5 ms VIB analog
      response time
      2 ms +/- 0.5 ms FM analog
      7 ms +/- 0.5 ms FLA, FLC discrete
      7 ms +/- 0.5 ms FLB, FLC discrete
      7 ms +/- 0.5 ms RY, RC discrete
      accuracy
      +/- 0.6 % VIA for a temperature variation 60 °C
      +/- 0.6 % VIB for a temperature variation 60 °C
      +/- 1 % FM for a temperature variation 60 °C
      linearity error
      +/- 0.15 % of maximum value input VIA
      +/- 0.15 % of maximum value input VIB
      +/- 0.2 % output FM
      analogue output number
      1
      analogue output type
      Switch-configurable voltage FM 0...10 V DC 7620 Ohm 10 bits
      Switch-configurable current FM 0...20 mA 970 Ohm 10 bits
      discrete output number
      2
      discrete output type
      Configurable relay logic FLA, FLC NO 100000 cycles
      Configurable relay logic FLB, FLC NC 100000 cycles
      Configurable relay logic RY, RC NO 100000 cycles
      minimum switching current
      3 mA 24 V DC configurable relay logic
      maximum switching current
      5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R
      5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R
      2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R
      2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R
      discrete input type
      Programmable F 24 V DC level 1 PLC 4700 Ohm
      Programmable R 24 V DC level 1 PLC 4700 Ohm
      Programmable RES 24 V DC level 1 PLC 4700 Ohm
      discrete input logic
      Positive logic (source) F, R, RES <= 5 V >= 11 V
      Negative logic (sink) F, R, RES >= 16 V <= 10 V
      acceleration and deceleration ramps
      Automatic based on the load
      Linear adjustable separately from 0.01 to 3200 s
      braking to standstill
      By DC injection
      protection type
      Motor phase break motor
      Break on the control circuit drive
      Thermal power stage drive
      Overvoltages on the DC bus drive
      Against exceeding limit speed drive
      Against input phase loss drive
      With PTC probes motor
      Input phase breaks drive
      Line supply overvoltage and undervoltage drive
      Line supply undervoltage drive
      Overcurrent between output phases and earth drive
      Overheating protection drive
      Short-circuit between motor phases drive
      Thermal protection motor
      dielectric strength
      3535 V DC between earth and power terminals
      5092 V DC between control and power terminals
      insulation resistance
      >= 1 MOhm 500 V DC for 1 minute
      frequency resolution
      0.024/50 Hz analog input
      0.1 Hz display unit
      communication port protocol
      METASYS N2
      BACnet
      APOGEE FLN
      LonWorks
      Modbus
      connector type
      1 open style
      1 RJ45
      physical interface
      2-wire RS 485
      transmission frame
      RTU
      transmission rate
      9600 bps or 19200 bps
      data format
      8 bits, 1 stop, odd even or no configurable parity
      type of polarization
      No impedance
      number of addresses
      1...247
      communication service
      Time out setting from 0.1 to 100 s
      Monitoring inhibitable
      Read device identification (43)
      Write single register (06)
      Read holding registers (03) 2 words maximum
      Write multiple registers (16) 2 words maximum
      option card
      Communication card LonWorks
      operating position
      Vertical +/- 10 degree
      width
      245 mm
      height
      330 mm
      depth
      190 mm
      product weight
      11.65 kg
      power dissipation in W
      723 W
      air flow
      214 m3/h
      discrete and process manufacturing
      Building - HVAC : compressor for scroll
      Building - HVAC : fan
      Building - HVAC : pump
      power range
      15...25 kW at 380...440 V 3 phases
      15...25 kW at 480...500 V 3 phases
      motor starter type
      Variable speed drive
      Environment
      electromagnetic compatibility
      Conducted radio-frequency immunity test level 3 IEC 61000-4-6
      Voltage dips and interruptions immunity test IEC 61000-4-11
      1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
      Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
      Electrostatic discharge immunity test level 3 IEC 61000-4-2
      Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
      pollution degree
      3 IEC 61800-5-1
      IP degree of protection
      IP20 on upper part without blanking plate on cover EN/IEC 61800-5-1
      IP20 on upper part without blanking plate on cover EN/IEC 60529
      IP21 EN/IEC 61800-5-1
      IP21 EN/IEC 60529
      IP41 on upper part EN/IEC 61800-5-1
      IP41 on upper part EN/IEC 60529
      vibration resistance
      1 gn 13...200 Hz EN/IEC 60068-2-8
      1.5 mm 3...13 Hz EN/IEC 60068-2-6
      shock resistance
      15 gn 11 ms IEC 60068-2-27
      environmental characteristic
      Classes 3C1 IEC 60721-3-3
      Classes 3S2 IEC 60721-3-3
      noise level
      59.9 dB 86/188/EEC
      operating altitude
      1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m
      <= 1000 m without derating
      relative humidity
      5...95 % without condensation IEC 60068-2-3
      5...95 % without dripping water IEC 60068-2-3
      ambient air temperature for operation
      -10...40 °C without derating
      > 40...50 °C with derating factor
      ambient air temperature for storage
      -25...70 °C
      standards
      IEC 61800-3 environments 2 category C1
      IEC 61800-3
      EN 61800-3
      EN 61800-3 environments 2 category C2
      EN 61800-3 category C2
      EN 61800-3 environments 1 category C1
      IEC 61800-5-1
      UL Type 1
      IEC 61800-3 environments 2 category C2
      IEC 61800-3 environments 2 category C3
      EN 61800-5-1
      EN 61800-3 environments 2 category C3
      EN 61800-3 category C3
      IEC 61800-3 category C3
      IEC 61800-3 environments 1 category C1
      IEC 61800-3 environments 1 category C2
      IEC 61800-3 category C2
      IEC 61800-3 environments 1 category C3
      EN 61800-3 environments 1 category C3
      EN 55011 class A group 1
      EN 61800-3 environments 2 category C1
      EN 61800-3 environments 1 category C2
      product certifications
      NOM 117
      CSA
      C-Tick
      UL
      marking
      CE
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)
      Compliant  - since  1050  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity
      REACh
      Product environmental profile
      Available
      Product end of life instructions
      Available
      Contractual warranty
      Warranty period
      18 months
    • Documents and Downloads

      Language
      • English
      • Chinese
      Catalogue
      Date
      Size
      Add to My Documents
      Date 6/20/18
      Size 16.6 MB
      User guide
      Date
      Size
      Add to My Documents
      Date 2/17/17
      Size 1.7 MB
      Date 4/28/17
      Size 978.7 KB
      Date 11/14/16
      Size 5.1 MB
      Date 12/14/17
      Size 1.1 MB
      Date 3/11/15
      Size 6.7 MB
      Date 12/13/17
      Size 3.5 MB
      Certificate
      Date
      Size
      Add to My Documents
      Date 6/19/18
      Size 57.2 KB
      Date 4/27/18
      Size 682.4 KB
      Date 7/14/18
      Size 120 KB
      Software - Released
      Date
      Size
      Add to My Documents
      SoMove V2.6.5 (FDT Standalone)
      Date 6/19/18
      Size 234.4 MB
      Date 6/19/18
      Size 107.1 KB
      DTM files
      Date
      Size
      Add to My Documents
      Altivar DTM Library V12.8: ATV12, ATV31/312, ATV32, ATV61, ATV71, ATV LIFT, ATV212
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
    • Dimensions Drawings

      Dimensions


      Plate for EMC mounting (supplied with the drive)


      (1)
      2 x M5 screws


    • Mounting and Clearance

      Mounting Recommendations
      Clearance

      Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories.

      Install the unit vertically:

      • Do not place it close to heating elements.

      • Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit.


      Mounting Types

      Type A mounting


      Type B mounting


      Type C mounting


      By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP21. The protective blanking cover may vary according to the drive model, see opposite.


      Specific Recommendations for Mounting in an Enclosure

      To help ensure proper air circulation in the drive:

      • Fit ventilation grilles.

      • Check that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics).

      • Use special filters with UL Type 12/IP54 protection.

      • Remove the blanking cover from the top of the drive.

      Sealed Metal Enclosure (IP54 Degree of Protection)

      The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions, such as dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc.This enables the drive to be used in an enclosure where the maximum internal temperature reaches 50°C.


    • Connections and Schema

      Recommended Wiring Diagram
      3-Phase Power Supply


      A1:
      ATV 212 drive
      KM1:
      Contactor
      Q1:
      Circuit breaker
      Q2:
      GV2 L rated at twice the nominal primary current of T1
      Q3:
      GB2CB05
      S1, S2:
      XB4 B or XB5 A pushbuttons
      T1:
      100 VA transformer 220 V secondary
      (1)
      Fault relay contacts for remote signalling of the drive status
      (2)
      Connection of the common for the logic inputs depends on the positioning of the switch (Source, PLC, Sink)
      (3)
      Reference potentiometer SZ1RV1202

      NOTE: All terminals are located at the bottom of the drive. Install interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc.

      Switches (Factory Settings)

      Voltage/current selection for analog I/O (VIA and VIB)


      Voltage/current selection for analog I/O (FM)


      Selection of logic type


      (1)
      negative logic
      (2)
      positive logic


      Other Possible Wiring Diagrams
      Logic Inputs According to the Position of the Logic Type Switch

      “Source” position


      “Sink” position


      “PLC” position with PLC transistor outputs


      (1)
      PLC


      (1)
      PLC

      2-wire control


      F:
      Forward
      R:
      Preset speed
      (2)
      ATV 212 control terminals

      3-wire control


      F:
      Forward
      R:
      Stop
      RES:
      Reverse
      (2)
      ATV 212 control terminals

      PTC probe


      (2)
      ATV 212 control terminals
      (3)
      Motor

      Analog Inputs

      Voltage analog inputs

      External +10 V


      (2)
      ATV 212 control terminals
      (4)
      Speed reference potentiometer 2.2 to 10 kΩ


      (2)
      ATV 212 control terminals

      Analog input configured for current: 0-20 mA, 4-20 mA, X-Y mA


      (2)
      ATV 212 control terminals
      (5)
      Source 0-20 mA, 4-20 mA, X-Y mA

      Analog input VIA configured as positive logic input (“Source” position)


      (2)
      ATV 212 control terminals

      Analog input VIA configured as negative logic input (“Sink” position)


      (2)
      ATV 212 control terminals


    • Performance Curves

      Derating Curves

      The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type (A, B or C).

      For intermediate temperatures (45°C for example), interpolate between 2 curves.


      X
      Switching frequency


    • Motor Starter BOM

      Our Proposal: Circuit Breaker + Contactor + Drive for Motor Power 22 kW and 380 VAC

      Motor power

      (kW)

      ICU

      (kA)

      Breaker

      Contactor (*)

      Motor Starter

      22

      50


      GV3L50


      LC1D32P7


      ATV212HD22N4S

      Non contractual pictures.

      (*) You can select the contactor proposed or variants. Please consider examples hereafter or follow the link to the complete offer.

      Motor power

      kW

      Coil voltage

      VAC - 50/60 Hz

      24

      48

      110

      115

      220

      230

      400

      Other

      22

      LC1D32 ..

      B7

      E7

      F7

      FE7

      M7

      P7

      V7

      Complete Offer

      Motor power

      kW

      Coil voltage

      VDC

      24

      48

      110

      125

      220

      230

      Other

      22

      LC1D32 ..

      BD

      ED

      -

      -

      -

      -

      Complete Offer

      Motor power

      kW

      Coil voltage

      Low Consumption

      VDC - U 0.8…1.25 Uc

      24

      110

      Other

      22

      LC1D32 ..

      BL

      FL

      Complete Offer